Troubleshooting - spray pattern – Chicago Electric HVLP-ELECTRIC 97750 User Manual

Page 14

Advertising
background image

Page 14

SKU 97750

For technical questions, please call 1-800-444-3353.

TROuBLESHOOTINg - SPRAY PATTERN

IMPORTANT:

Improper cleaning is a common reason for the unit not to work properly.

Most problems can be avoided or remedied with prompt, thorough cleaning.

The illustrations below resemble symptoms of spray pattern problems.

Refer to the illustration your Spray Gun may be experiencing. Then refer to the

“Possible Causes” and “Possible Solutions” sections.

Problem

Possible Causes

Possible Solutions

Fluid Control Screw (19) is

1.

partially closed.
Fluid is too thick.

2.

Air pressure is too low.

3.

Open Fluid Control Screw

1.

(19).
Thin material according to

2.

manufacturer’s instructions.
Adjust Air Control Lever (13).

3.

Air pressure is too high.

1.

Not enough fluid.

2.

Fluid Control Screw (19) open

3.

too much.

Adjust Air Control Lever (13).

1.

Refill Cup (27).

2.

Partially close Fluid Control

3.

Screw (19).

Air Nozzle (4) plugged.

1.

Air Nozzle (4) loose, or dirty

2.

Seat.
Dried material on fluid tip.

3.

Clean Air Nozzle (4).

1.

Clean and tighten.

2.

Use a non-metallic point to

3.

clean the Air Nozzle (4).

Dirt on one side of the fluid

1.

tip.
Holes on one side of the Air

2.

Nozzle (4) are plugged.

Clean the fluid tip.

1.

Use a non-metallic point to

2.

clean the Air Nozzle (4).

Follow all safety precautions whenever diagnosing or servicing the

tool. disconnect power supply before service. If the steps above

do not solve the problem, or if the repairs involved are too complex,

contact a qualified service technician.