Chicago Electric HVLP-ELECTRIC 97750 User Manual

Page 9

Advertising
background image

Page 9

SKU 97750

For technical questions, please call 1-800-444-3353.

Work Piece and Work Area Set up

Designate a work area that is clean

1.

and well-lit. The work area must not

allow access by children or pets to

prevent injury and distraction.
Route the Power Cord (34) along a

2.

safe route to reach the work area

without creating a tripping hazard

or exposing the Power Cord to pos-

sible damage. The Power Cord must

reach the work area with enough

extra length to allow free movement

while working.
Secure loose workpieces using a vise

3.

or clamps (not included) to prevent

movement while working.
There must not be hazardous ob-

4.

jects, such as utility lines or foreign

objects, nearby that will present a

hazard while working.
Cover all furniture, decorations,

5.

floors, walls, etc. not intended to be

painted.
Only paint in well ventilated dust free

6.

area.

Tool Set up

Mix and thin the paint or other fluid

1.

thoroughly according to the manufac-

turer’s directions.
Carefully strain the paint/fluid through

2.

a paint strainer or piece of cheese

cloth.
Fill the Cup (27) to approximately

3.

3/4 full. Then attach the Cup to the

Spray Gun.

(See Figure A, on page

8.)

Plug the Power Cord (34) into the

4.

nearest 120 volt, grounded, electrical

outlet. Then turn the Power Switch

(33) to its “ON” position.

(See Figure A, on page 8.)
Adjust the air pressure during op-

5.

eration with the Trigger (6) and the

Air Control Lever (13). Turn the Air

Control Lever clockwise to provide

less air to the Spray Gun. Turn the

Air Control Lever counterclockwise

to provide more air to the Spray Gun.

(See Figure A, on page 8.)
Set up a piece of scrap material to

6.

practice on. While practicing on the

scrap material, check to see that the

paint/fluid you are spraying has the

appropriate consistency. If it appears

too thick, add a very small amount of

thinner (not included).
To change the direction of the fan

7.

from horizontal to vertical, loosen the

Air Cap Screw (5) and turn the Air

Nozzle (4) 90 degrees. After the ad-

justment, tighten the Air Cap Screw.

(See Figure B.)

To set the pattern size specific to the

8.

job, use the Fluid Control Screw (19).

Turn it clockwise for a round pattern.

Turn the Screw counterclockwise (all

the way open) to flatten the pattern.

(See Figure C, next page.)

FIguRE B

HORIZONTAL FAN

VERTICAL FAN

AIR NOZZLE (4)

AIR CAP SCREW (5)

Advertising