4 connector x1b row c, Connector x1b row c, Come-cpc2 / connectors – Kontron COMe-cPC2 User Manual

Page 61

Advertising
background image

COMe-cPC2 / Connectors

5.2.4

Connector X1B Row C

Pin

Signal

Description

Type

Termination

Comment

C1

GND

Power Ground

PWR

-

-

C2

IDE_D7

IDE Data Bus

I/O-5T

PD 10k

-

C3

IDE_D6

IDE Data Bus

I/O-5T

-

-

C4

IDE_D3

IDE Data Bus

I/O-5T

-

-

C5

IDE_D15

IDE Data Bus

I/O-5T

-

-

C6

IDE_D8

IDE Data Bus

I/O-5T

-

-

C7

IDE_D9

IDE Data Bus

I/O-5T

-

-

C8

IDE_D2

IDE Data Bus

I/O-5T

-

-

C9

IDE_D13

IDE Data Bus

I/O-5T

-

-

C10

IDE_D1

IDE Data Bus

I/O-5T

-

-

C11

GND

Power Ground

PWR

-

-

C12

IDE_D14

IDE Data Bus

I/O-5T

-

-

C13

IDE_IORDY

IDE I/O Ready

I/O-5T

PU 4k7 3,3V (S0)

-

C14

IDE_IOR#

IDE I/O Read

I/O-3,3

-

-

C15

PCI_PME#

PCI Power Management Event

I/O-3,3

-

int. PU 20k in ICH9

C16

PCI_GNT2#

PCI Bus Grant 2

O-3,3

-

int. PU 20k in ICH9 (if PCIRST#=0 AND
PWROK=1)

C17

PCI_REQ2#

PCI Bus Request 2

I-5T

PU 8k2 3,3V (S0)

-

C18

PCI_GNT1#

PCI Bus Grant 1

O-3,3

-

int. PU 20k in ICH9 (if PCIRST#=0 AND

PWROK=1)

C19

PCI_REQ1#

PCI Bus Request 1

I-5T

PU 8k2 3,3V (S0)

-

C20

PCI_GNT0#

PCI Bus Grant 0

O-3,3

PD 1k0

int. PU 20k in ICH9 (if PCIRST#=0 AND
PWROK=1)

C21

GND

Power Ground

PWR

-

-

C22

PCI_REQ0#

PCI Bus Reqest 0

I-5T

PU 8k2 3,3V (S0)

-

C23

PCI_RST#

PCI Bus Reset

O-3,3

-

-

C24

PCI_AD0

PCI Adress & Data Bus line

I/O-5T

-

-

C25

PCI_AD2

PCI Adress & Data Bus line

I/O-5T

-

-

C26

PCI_AD4

PCI Adress & Data Bus line

I/O-5T

-

-

C27

PCI_AD6

PCI Adress & Data Bus line

I/O-5T

-

-

C28

PCI_AD8

PCI Adress & Data Bus line

I/O-5T

-

-

C29

PCI_AD10

PCI Adress & Data Bus line

I/O-5T

-

-

C30

PCI_AD12

PCI Adress & Data Bus line

I/O-5T

-

-

C31

GND

Power Ground

PWR

-

-

C32

PCI_AD14

PCI Adress & Data Bus line

I/O-5T

-

-

C33

PCI_C/BE1#

PCI Bus Cmd Byte enables 1

I/O-5T

-

-

C34

PCI_PERR#

PCI Bus Grant Error

I/O-5T

PU 8k2 3,3V (S0)

-

C35

PCI_LOCK#

PCI Bus Lock

I/O-5T

PU 8k2 3,3V (S0)

-

C36

PCI_DEVSEL#

PCI Bus Device Select

I/O-5T

PU 8k2 3,3V (S0)

-

C37

PCI_IRDY#

PCI Bus Bus Initiator Ready

I/O-5T

PU 8k2 3,3V (S0)

-

C38

PCI_C/BE2#

PCI Bus Cmd Byte enables 2

I/O-5T

-

-

C39

PCI_AD17

PCI Adress & Data Bus line

I/O-5T

-

-

C40

PCI_AD19

PCI Adress & Data Bus line

I/O-5T

-

-

C41

GND

Power Ground

PWR

-

-

C42

PCI_AD21

PCI Adress & Data Bus line

I/O-5T

-

-

C43

PCI_AD23

PCI Adress & Data Bus line

I/O-5T

-

-

C44

PCI_C/BE3#

PCI Bus Cmd Byte enables 3

I/O-5T

-

-

C45

PCI_AD25

PCI Adress & Data Bus line

I/O-5T

-

-

C46

PCI_AD27

PCI Adress & Data Bus line

I/O-5T

-

-

C47

PCI_AD29

PCI Adress & Data Bus line

I/O-5T

-

-

C48

PCI_AD31

PCI Adress & Data Bus line

I/O-5T

-

-

C49

PCI_IRQA#

PCI Bus Interrupt Request A

I-5T

PU 8k2 3,3V (S0)

-

C50

PCI_IRQB#

PCI Bus Interrupt Request B

I-5T

PU 8k2 3,3V (S0)

-

C51

GND

Power Ground

PWR

-

-

C52

PEG_RX0+

PCIexpress Graphics Recieve + (0)

DP-I

-

-

C53

PEG_RX0-

PCIexpress Graphics Recieve - (0)

DP-I

-

-

C54

TYPE0#

n.c. for type 2 module

nc

-

-

C55

PEG_RX1+

PCIexpress Graphics Recieve + (1)

DP-I

-

-

C56

PEG_RX1-

PCIexpress Graphics Recieve - (1)

DP-I

-

-

C57

TYPE1#

n.c. for type 2 module

nc

-

-

C58

PEG_RX2+

PCIexpress Graphics Recieve + (2)

DP-I

-

-

C59

PEG_RX2-

PCIexpress Graphics Recieve - (2)

DP-I

-

-

C60

GND

Power Ground

PWR

-

-

C61

PEG_RX3+

PCIexpress Graphics Recieve + (3)

DP-I

-

-

C62

PEG_RX3-

PCIexpress Graphics Recieve - (3)

DP-I

-

-

61

Advertising