Only use battery chargers with a maxi-

mum charging voltage of 14.8 V.

!

Only charge the battery using the jump-

starting connection point.

If, at low temperatures, the indicator lamps/

warning lamps in the instrument cluster do

not light up, it is highly likely that the dis-

charged battery has frozen. In this case you

may neither jump-start the vehicle nor charge

the battery. The service life of a thawed-out

battery may be shorter. The starting charac-

teristics can be impaired, particularly at low

temperatures. Have the thawed-out battery

checked at a qualified specialist workshop.
Never charge a battery still installed in the

vehicle unless a battery charger unit

approved by Mercedes-Benz is being used. An

accessory battery charge unit specially adap-

ted for Mercedes-Benz vehicles and tested

and approved by Mercedes-Benz is available.

It permits the charging of the battery in its

installed position. Contact an authorized

Mercedes-Benz Center for further informa-

tion and availability. Charge the battery in

accordance with the separate instructions for

the battery charger.
The jump-starting connection point is in the

engine compartment (

Y

page 391).

Read the battery charger's operating instruc-

tions before charging the battery.

X

Open the hood.

X

Connect the battery charger to the positive

terminal and ground point in the same

order as when connecting the donor bat-

tery in the jump-starting procedure

(

Y

page 391).

390