Pg07 install_frm assy 1, Ad-375 thermal door – Oldcastle BuildingEnvelope AD-375 Thermal Entrance User Manual

Page 9

Advertising
background image

DOOR FRAME ASSEMBLY

1. Attach (2) AC-133-01 shear blocks to top end of door jambs using (4) FS-9 #14 x 1 1/2" hex

head fasteners. See FIGURE 1.

2. Attach AD-204-01 left hand or AD-205-01 right hand threshold clips to bottom of door jamb

using (2) FS-62 #10 x 1/4" flat head machine screws. See FIGURE 3, pg 8.

3. Apply sealant along exterior and interior faces of shear blocks as shown in FIGURE 2, pg 8.

4. Assemble door header to jambs by sliding header over shear blocks and attaching using (2)

FS-7 #10 x 3/4" flat head screws. Clean excess sealant from exposed surfaces after assembly.

5. Attach threshold to clips using (1) FS-62 #10 x 1/4" flat head fasteners, See FIGURE 4, pg. 8.

Note; threshold will be removed once frame is installed into opening to seal and drill for

anchors.

6. Assembly of common lock mullions; use (2) AC-130 shear blocks mounted beneath door

header and attach with (4) FS-9 fasteners. Mullion will attach to shear blocks using (4) FS-7

#10 x 3/4" PFH screws. See FIGURE 5, pg 9.

7. Assembly of common hinge mullions; use (4) AC-130 shear blocks mounted beneath door

header and attach with (8) FS-9 fasteners. Mullion will attach to shear blocks using (4) FS-7

#10 x 3/4" PFH screws. See FIGURE 6, pg 10. When using the AD-452 common hinge mullion

between sets of doors, run mullion through and attach AD-450 door header as shown below.

FIGURE 1

Shear block installation

AC-133-01

FS-9

3/8"

5/16"

7/8"

5/16"

7/8"

Drill #11 (.191Ø) holes

AD-452

Common Hinge Mullion

Typical Door Jamb

Phone: 1-866-OLDCASTLE (653-2278)

Web Address: www.oldcastlebe.com

7

MAY 2013

AD-375 THERMAL DOOR

(2) FS-7

Advertising