1 continuous output (stream) format, Figure 8-1. continuous output format, 2 extended format – Rice Lake 120 Plus Digital Weight Indicator User Manual
Page 48: Figure 8-2. continuous output format, Figure 8-3. continuous output format, All values are ascii code characters, Extend 1: (if cinstr = on), Extend 2: (if monbat = on)

44
120Plus Digital Weight Indicator Technical Manual
8.3.1
Continuous Output (Stream) Format
All values are ASCII code characters.
Figure 8-1. Continuous Output Format
8.3.2
Extended Format
• Extend 1: (If CINSTR = ON)
Figure 8-2. Continuous Output Format
• Extend 2: (If MONBAT = ON)
Figure 8-3. Continuous Output Format
ASCII 02
Weight data: 7 digits, right-justified, with
decimal point, leading zero suppression,
Error = - - - - - -
G= Gross
Extend 1 Fromat:
See below
N= Net
Polarity
L=pounds
K=kilogram
G=grams
O= ounces
Status:
<space>=valid
I= Invalid
M= In motion
H= In Hold
<CR> <LF>
or<CR>
ASCll 13, 10
(Decimal)
<STX>
<wwwwww>
<UNIT>
<G/N>
<S>
<Extend 1>
<TERM>
Extend 2 Fromat:
See below
<Extend 2>
<Space>
<Time>
Time:
<Space>
<Date>
8 digits, hh:mm:ss
hh: 00~24
mm: 00~59
ss: 00~59
Date: 10 digits
yyyy/mm/dd if DATFRM= YYMMDD
dd/mm/yyyy if DATFRM= DDMMYY
mm/dd/yyyy if DATFRM= MMDDYY
yyyy: 2000-2009
mm: 01-12
dd:01~31
ASCII 32
(Decimal)
ASCII 32
(Decimal)
<Space>
<Voltage>
<Current>
Battery Voltage
<Space>
8 digits, d.dddddV
ASCII 32
(Decimal)
ASCII 32
(Decimal)
0.00000V~4.50000V
Battery Charging Current
8 digits, d.dddddA
0.00000A~1.00000A