Appendix D Error Messages
The 120 Plus indicator displays a number of error messages. When an error occurs, the message is shown on the
indicator LED display.
8.5
Appendix E Front Panel Display Characters
Figure 8-4. 120 Plus Display Characters
Error Message
Description
Solution
EMPTY SCREEN
Gross > Overload limit
Gross value exceeds overload limit. Check configuration or
signal input level.
UNDER DASHES
Underflow error
Weight value too small to be displayed
OVER DASHES
Overflow error
Weight value too large to be displayed
AD LOW
A/D over negative range
Check scale for binding or damage
AD HI
A/D over positive range
Check scale for binding or damage
EE SUM
Parameter or calibration check- sum error
Recalibration is needed; contact Rice Lake Weighing Systems
service
WW WR
EEPROM write error
Contact Rice Lake Weighing Systems service
PM SUM
Internal program checksum error
Contact Rice Lake Weighing systems service
HOFSET
Load > calibrated zero + capacity x INIZR
Check weight and INIZR
LOFSET
Load < calibrated zero + capacity x INIZR
Check weight and INIZR
UOFSET
Unstable within 2 sec of powering on
Check weight and INIZR
Table 8-15. Error Messages
%
&
’
(
)
*
/
0
1
2
3
4
5
6
;
<
=
>
?
@
A
B
G
H
I
J
K
L
M
N
S
T
U
V
W
X
Y
Z