10.2 Default Ticket Formats
Table 10-2 shows the default print formats for the
520
and lists the conditions under which each print format is
used. The HDRFMT format is used to specify header information that can be used by the other ticket formats. The
contents of the HDRFMT format can be inserted into any other ticket format using the <AE> formatting command.
Table 10-2. Default Print Formats
Format
Default Format String
Used When
GFMT
GROSS<G><NL2><TD><NL>
Normal mode, no tare in system
NFMT
GROSS<G><NL>TARE<SP><T><NL>NET<SP2><
N>
<NL2><TD><NL>
Normal mode, tare in system
CFMT
GROSS<G><NL>TARE<SP><T><NL>NET<SP2><
N><NL>COUNT<C><NL>APW<SP2><W><NL>
Count mode
SPFMT
<SCV><SP><SPM><NL>
Setpoint push print operation (PSHPRNT=ON)
EDPFMT
GROSS<G><NL2><TD><NL>
Normal mode, PRNDEST=BOTH (SERIAL menu). GFMT
(or NFMT) print format is sent to printer port
simultaneously.
HDRFMT
COMPANY NAME<NL>STREET ADDRESS<NL>
CITY, ST ZIP<NL2>
Inserted into another print format to specify header
information.
STRMFMT
<2><P><W7.><U><M><S><CR><LF>
Port print format set to CUSTOM (see Section 12.7 on
page 77).
Note
In OIML and CANADA modes, the letters PT (preset tare) are automatically inserted after the printed tare
weight.
For most applications, when using a printer attached to the EDP port, set PRNDEST (on the SERIAL menu)
to EDP. If PRNDEST=BOTH, only the EDP format is sent to the printer.
10.3 Customizing Print Formats
The following sections describe procedures for customizing print formats using the EDP port, the front panel
(PFORMT menu), and the Revolution® configuration utility. See Section 12.7 on page 77 for information about
custom stream formatting.
<SPnn>
Space (nn = number of spaces)*
<SU>
Toggle weight data format (formatted/unformatted)**
NOTES:
Gross, net, tare and setpoint values are 9 digits in length, including sign (10 digits with decimal point), followed by a space and
a two-digit units identifier. Total field length with units identifier is 12 (or 13) characters.
ID and consecutive number (CN) fields are 1–7 characters in length, as required.
ID numbers included in the print format string (<ID> command) must be set using the UID EDP command or via keypad in
setup mode.
Ticket header (AE) inserts information specified for the HDRFMT header format.
* If nn is not specified, 1 is assumed. Value must be in the range 1–99.
** After receiving an SU command, the indicator sends unformatted data until the next SU command is received. Unformatted
data omits decimal points, leading and trailing characters.
Note
Command
Description
Ticket Format
GFMT/NFMT/EDPFMT
/CFMT
SPFMT
Table 10-1. Print Format Commands (Continued)