14 EtherNet/IP Installation and Programming Manual
16
0x010
Primary Units
17
0x011
Secondary Units
18
0x012
Tertiary Units
19
0x013
Units key press (toggle units)
20
0x014
Print Request
21
0x015
Display Accumulator
22
0x016
Clear Accumulator
23
0x017
Push Weight to Accumulator
32
0x020
Return Gross (integer)
33
0x021
Return Net (integer)
34
0x022
Return Tare (integer)
37
0x025
Return Current Display (integer)
38
0x026
Return Accumulator (integer)
95
0x05F
Set Batching State
96
0x060
Batch Start
97
0x061
Batch Pause
98
0x062
Batch Reset
99
0x063
Batch Status
112
0x070
Lock Indicator Front Panel
113
0x071
Unlock Indicator Front Panel
114
0x072
Set Digital Output ON
115
0x073
Set Digital Output OFF
116
0x074
Read Digital I/O Status
128
0x80
Enable Bus Command Handler
253
0x0FD
No operation
254
0x0FE
Reset Indicator
256
0x100
Return Status and Weight (float)
268
0x10C
Enter Tare (float)
288
0x120
Read Gross (float)
289
0x121
Read Net (float)
290
0x122
Read Tare (float)
293
0x125
Read Current Display (float)
294
0x126
Read Accumulator (float)
304
0x130
Set Setpoint Value (float)
305
0x131
Set Setpoint Hysteresis (float)
306
0x132
Set Setpoint Bandwidth (float)
307
0x133
Set Setpoint Preact (float)
320
0x140
Read Setpoint Value (float)
321
0x141
Read Setpoint Hysteresis (float)
322
0x142
Read Setpoint Bandwidth (float)
323
0x143
Read Setpoint Preact (float)
Decimal
Hex
Command
Table 4-2. Remote Commands (Continued)