2 status data, Status data – Rice Lake 880 Performance Series Panel Mount Indicator/Controller - EtherNet/IP Interface Option Installation and Programming Manual User Manual
Page 20

16 EtherNet/IP Installation and Programming Manual
4.2.2
Status Data
Indicator status data is returned in the second word (see Table 4-4). Batch commands
return batch status in place of the low byte (see Table 4-5). Setpoint commands return
batch status in the low byte of the status word and the setpoint number in the high
byte.
Bit-0 Errors
• PLC command failed to execute.
• No configuration has taken place.
• Scale parameter is out of range.
• Print error has occurred.
• Load error has occurred.
• Memory error has occurred.
• Analog to digital converter error.
• Tare error.
• Scale over range error.
• Scale under range error.
• Non-recoverable configuration store error.
• Indicator in configuration mode.
Word 2
Bit
Indicator Status Data
Value=0
Value=1
00
Error **
(see See “Bit-0 Errors” on
page 16.)
No error
01
Tare not entered
Tare entered
02
Not center of zero
Center of zero
03
Weight invalid
Weight OK
04
Standstill
In motion
05
Primary units
Other units
06
Tare not acquired
Tare acquired
07
Gross weight
Net weight
08
Channel number
Least significant bit first.
09
10
11
12
13
Not used
14
Integer data
Floating point data
15
Positive weight
Negative weight
** This error condition does not necessarily mean the weight
being reported is invalid. Refer to the “Weight invalid” bit.
Table 4-4. Indicator Status Data Format
Note