3 junction box installation – Rice Lake BCi Belt Scale - Installation and Operation Manual Version 2.03 User Manual
Page 23
Advertising
Installation and Operation Manual- Integrator Hardware Installation
17
2.3
Junction Box Installation
The In-Motion Belt Scale uses the TuffSeal
JB4SS (PN 88956) junction box. It is a four-channel signal trim
junction box with an expansion board enclosed. The junction box is a stainless steel NEMA 4X enclosure that
comes with a standard Prevent
®
breather vent which inhibits the buildup of pressure cause by sudden temperature
or environmental changes.
Figure 2-4. TuffSeal Junction Box
Use the following steps to install the junction box.
1. Set the junction box onto the uni-strut center bar and attach to the bar using the enclosed screws.
2. Attach the ground lug (shown below).
Figure 2-5. Attach the Ground Lug onto the Junction Box