4 attaching the idlers to the scale carriage – Rice Lake BCi Belt Scale - Installation and Operation Manual Version 2.03 User Manual
Page 27
Installation and Operation Manual- Integrator Hardware Installation
21
2.4
Attaching the Idlers to the Scale Carriage
Once the scale carriage is assembled, you can mount the idlers to the carriage.
Mount the idlers
to t he ca r ri ag e
using the V-bolts
and bolting them
to t he ca r ri ag e
frame.
Note:
V- b o l t s c a n b e
p u rc h a s e d
separately from
RLWS.
PN 98806 - fits 3"
angles
PN 99323 - fits 4"
angles
Figure 2-11. Mount Idlers to Scale Carriage
Figure 2-12. Mount Idlers to Scale Carriage Using V-Bolts
Mount the idlers to the scale carriage using the large V-bolts and bolting them to the scale carriage frame.
If the scale carriage requires the relocation of cross bracing directly under the scale. Any bracing that is removed
should be relocated or replaced as to not reduce the structural integrity of the conveyor. The minimum clearance
under the scale is 6.50" as measured from the top mounting surface. If the return conveyor belt is less than 6.50"
from the top of the frame, then the scale carriage will require extra shimming or the return idlers will require
relocation. The return side of the conveyor belt must not contact the bottom of the scale when the conveyor is
operating.