Table 4-5. CLS-920i Serial Menu Parameters

SERIAL Menu

Parameter

Choices

Description

Level 2 submenus

PORT 1
PORT 2
PORT 3
PORT 4

PORT x

CMD
PROGIN
KEYBD
SCALE
IND SC
IQUBE

Specifies the type of data received by the port:

CMD:

Remote command input

PROGIN: Programmable input
KEYBD:

Remote keyboard input

SCALE:

Legal-for-trade serial scale input

IND SC:

Industrial (non-legal-for-trade) scale input

IQUBE:

iQUBE

serial scale input

KEYBD is available only on Port 2; SCALE, IND SC, IQUBE, and HIPREC are available only on
Ports 3 and 4 and higher (expansion ports).

Note

The keyboard interface is not hot-pluggable. Power-off the

920i

before

plugging the keyboard cable into the Port 2 connector.

Level 3 Submenus

Port 1–Port 32

CONFIG

4/0/0/0
8/0/0/0
8/4/0/0
8/4/4/0
8/8/0/0
4/4/0/0
4/4/4/0
4/4/4/4
4/8/0/0

iQube board configuration.

CELLS

CELLA1
CELLA2
CELLA3
CELLA4

iQube load cell configuration

SECTION

PAIRED
CIRCULAR

iQube section definition

PLATFRM

A1
A2

iQube platform definition

SYSTEM

PLATFRM1

iQube platform definition

ALGOUT

SOURCE
FULLSC

iQube analog output definition

DIGIO

Leave at
default setting

iQube digital I/O configuration

IQDIAG

Leave at
default setting

iQube diagnostics parameter

TESTCOM

VALIDATE

iQube communications tester

PORTTYPE

232
485

Specifies whether Port 4 is used for RS-232 or RS-485 communications. If 485 is selected,
additional prompts are shown to specify half- or full-duplex operation and RS-485 address.

Note

RS-485 communications can be specified for Port 4, and for odd numbered
expansion ports 5 and higher.

36

CLS-920i Installation Manual