Introduction, Specifications, Controls – Rice Lake Intercomp CS 750 - Users Manual User Manual
Page 3: Electrical, Performance, Environmental, Physical

CS750, Users
Rev R, May 2009
Page 3 of 27
Introduction
This manual contains specifications, operation instructions, and calibration instructions
for Intercomp's model CS750 crane scale.
Specifications
Controls
General:
Zero, On, Off, Backlight
Display:
5 digit LCD.
Indicators: lb, kg.
Electrical
Batteries:
6 X D-size disposable alkaline dry cells or rechargeable Nickel-
Cadmium cells.
Battery life:
Up to 250 hours with alkaline batteries. Approximately 80 hours
on a set of fully charged Ni-Cad cells.
Resolution:
20 bit A/D delivers over 1,000,000 internal counts.
Filtering:
6 Pole, 10 Hertz low pass.
Auto off:
Low battery, or after adjustable time without use or motion.
Sleep
mode:
Display sleep mode after adjustable time without use or motion.
Auto-Zero:
Satisfies all HB-44 requirements; selectable 0.6, 1, or 3
graduations.
Performance
Accuracy: ±0.1% of applied load or ± display graduation, whichever is greater.
Environmental
Humidity:
10 to 95% Non-Condensing
Temperature:
Storage: -40 C to +75 C. / -40 F to +170 F.
Operating -10 C to +50 C. / +14 F to +122 F.
Physical
Dimensions:
Control Box:
4.25" x 5" x 8.5". / 10.8 cm X
12.7 cm x 21.6 cm.
Lifting eye to hook (Standard):
12" / 30.5 cm.
Weight:
7.5 lb. / 3.4 kg.