3 mounting, 1 pr 6002/02s, ../03s, Installation manual mounting kits pr 6002 – Rice Lake PR6202 Hygienic Weigh Module Kits User Manual
Page 21
Installation Manual
Mounting Kits PR 6002
Sartorius
EN-19
4.3
Mounting
4.3.1 PR 6002/02S, ../03S
Note:
The following steps must be performed at all supporting points of the weighing
object (e.g. vessel)!
• Put the mounting kit on the foundation (7) and tighten the bolts (5) lightly.
• Place the weighing object (1) on the mounting kit and adjust the mounting kit position over the
bore holes.
• Adjust the position of the washers over the bore holes so that the bore holes are covered.
• Tighten the bolts (3) of the upper mounting plate (2) and the bolts (5) of the lower mounting
plate (6) with the recommended tightening moment, see Chapter 4.2.
• Lift the weighing object (1) approx. 5 mm, a required lifting tool.
• Clean the load cell base in both load disks.
• Protect the contact surfaces between load cell/load disks with sufficient grease
.
• Position and install the load cell (4) using the rubber ring for mounting, see Chapter 2.4.
• Put the weighing object (1) again on the mounting kit, using a required lifting tool.
• Remove the rubber ring, see Chapter 2.4.