Mounting kits pr 6002 installation manual – Rice Lake PR6202 Hygienic Weigh Module Kits User Manual
Page 22
Mounting Kits PR 6002
Installation Manual
EN-20
Sartorius
4.3.2 PR 6002/04S, ../05S, ../10S, ../11S, ../20S, ../21S
Note:
The following steps must be performed at all supporting points of the weighing
object (e.g. vessel)!
Note:
The mounting kit must be installed so that the access side is easily accessible (in most
installations, this side will face outwards). The load cell is inserted via the access side. The
transport protection can be removed easily.
Note:
For PR 6002/10S, ../11S, ../20S, ../21S only:
Adjustment of the constrainer is
not necessary.
• Put the mounting kit on the foundation (6) and tighten the bolts (8) lightly.
• Place the weighing object (1) on the mounting kit and adjust the mounting kit position over the
bore holes.
• Adjust the position of the washers over the bore holes so that the bore holes are covered.
• Tighten the bolts (4) of the upper mounting plate (5) and the bolts (8) of the lower mounting
plate (7) with the recommended tightening moment, see Chapter 4.2.
• Lift the weighing object (1) approx. 5 mm, using a required lifting tool remove the transport
protections (2, 3), see Chapter 2.2.