is high, take the appropriate steps at this time to add NEW, or empty USED fluid(s). See page
13 for instructions.

Note: The unit defaults to QUARTS measurement upon start up. LITERS may be selected by

depressing the “Q/L” button. The LED indicates which unit of measure is being
utilized.

4)

Start vehicle. Fluid pressure should now increase on the pressure gauge located on the front

panel of the unit, the READY light will remain on, and a continuous alert indication will
sound.

WARNING: If zero pressure is displayed on the pressure gauge and the continuous alert

does not sound upon vehicle start up, then IMMEDIATELY turn the vehicle
off and switch the new and used hose connections at intermediate hose
locations.

Once the hoses have been switched, repeat the above procedure and verify that READY light
comes on and alert indication sounds. This indicates that the proper connections have been
made and the fluid is flowing in the right direction. Unit is now in bypass mode with fluid
simply flowing through the unit and returning to vehicle.

Alert buzzer indication will continuously sound until COOLER LINE mode is selected. To
silence alert, select COOLER LINE mode or turn off the vehicle.

5)

Select COOLER LINE mode. LED will turn on and remain lit, the continuous alert will stop,

READY light will remain lit, NEW tank readout defaults to 12 quarts.


6)

Set the amount of fluid to be exchanged in one-tenth quart or liter increments, increasing or

decreasing the volume by depressing “+” or “-“ buttons until the desired quantity to be
exchanged is reached. This amount will be displayed in the NEW fluid readout on the top left
of the control panel.

7)

Press EXCHANGE START. READY light will go out and the value on the NEW fluid readout

will begin to decrease as new fluid is being pumped into the vehicle. Amount shown in the
NEW fluid readout also represents the remaining amount of new fluid left to exchange.

USED fluid readout will begin to increase from zero as the USED fluid from the vehicle enters
the USED fluid tank of the unit. The USED fluid readout depicts amount of USED fluid
removed from the vehicle during exchange.

NOTE: If NEW fluid tank does not have enough fluid to perform the exchange or USED fluid

tank does not have enough capacity to perform the exchange, appropriate LED will
light and beep indicating LOW TANK LEVEL in NEW tank and/or HIGH TANK
LEVEL in USED tank. Take the appropriate actions to correct fluid levels and repeat
Steps 3-7. The STOP button must be pushed to reboot system. See page 13 for
instructions.

NOTE: Should pressure drop below

4 psi

during exchange for any reason, the

ATF1defaults

to a bypass circuit and a continuous alarm will sound to alert that the exchange has
stopped. Upon correction of the problem, process will require restating from step #4.

8)

Upon completion of the fluid exchange, alarm will sound, READY light will turn on, and unit

will automatically go into bypass mode.