7.

At completion of exchange, Ready Light will turn on and Alarm sounds.

8.

Check fluid level, add or extract fluid if necessary.

9.

Turn off vehicle – Disconnect RED and Black hoses – Disconnect adapters – Reconnect

cooler line.

10.

Start vehicle to check for leaks and recheck fluid level.


Dipstick Exchange

**NOTE: VEHICLETRANSMISSION FLUID SHOULD BE AT OPERATING TEMPERATURE PRIOR
TO PERFORMING ANY SERVICE WITH THE ATF1.

**NOTE:THE ON BOARD BATTERY SHOULD BE AT FULL CHARGE FOR MOST EFFICIENT

FLUID EXCHANGE SERVICE, make it a habit to plug the on board battery charger into a
110 volt service outlet after every 3 to 4 fluid services for efficiency and extended battery life

.

1)

Connect red and black hoses from unit to the matching colored male connectors on the dipstick

flow control valve. Connect the dipstick extraction/addition wand attachment to the female
coupler on the dipstick flow control valve. Insert the dipstick wand into the transmission fluid
fill tube as far as it will reach without excessively forcing wand.


2)

Connect the ATF1battery terminals to the vehicle’s 12v battery, making sure to observe all

applicable safety precautions. Should the connection inadvertently be reversed, REVERSE
POLARITY light will be lit, along with a steady audible alarm, until the correct connection is
made.

Once correct battery connection is made, turn Main Power switch to the ON position. Alarm
will sound for two seconds, all of the LED’s will momentarily turn on, the POWER and
READY lights will turn on and the NEW and USED readouts will display quantities of
corresponding fluid in each tank. If fluid in the NEW tank is too low or the fluid in the USED
tank is too high, take the appropriate steps at this time to add NEW, or empty USED fluid(s).
See page 13 for instructions.

3)

Select DIPSTICK mode. LED light will remain on during the entire process until it is

complete. Displays default to 12.0 quarts.

4)

Enter the total amount of fluid to be exchanged using the increase (+), or decrease (-) buttons

until desired amount of fluid to be exchanged is displayed in NEW fluid display.

5)

Select DRAIN PAN function. USED fluid will now be removed from vehicle.USED fluid

display will increase as USED fluid is removed from the vehicle. NEW fluid display will
indicate the remaining amount to be exchanged between each cycle or NEW fluid to be added.

Unit will sense when all of USED fluid has been removed from vehicle when USED fluid
levels cease to change for a period of twenty seconds. This step is complete when DRAIN PAN
LED turns off, READY light turns on, and Alarm sounds.

NOTE: If NEW fluid tank does not have enough fluid to perform the exchange amount

selected or USED fluid tank does not have enough capacity to perform the exchange
amount selected, the appropriate LED will flash and beep indicating LOW TANK
LEVEL in NEW tank and/or HIGH TANK LEVEL in USED tank. Take the
appropriate action to correct and then repeat Step 7. See page 13 for instructions.