INSTALLATION RESTRICTIONS

WARNING

Failure to install, maintain and/or operate the CSA1 in accordance with manufacturer's instructions may result in conditions
which can produce bodily injury and property damage.

The CSA1 must be installed by a qualified installer in accordance with these instructions and all local codes or in their
absence in accordance with the latest editions of The National Fuel Gas Code (NFPA #54), Chimneys, Fireplaces, Vents, and
Solid Fuel Burning Appliances (NFPA 211), and the Occupational Safety and Health Act (OSHA) when applicable. Improper
installation can create a hazardous condition such as an explosion, fire, electrical shock or carbon monoxide poisoning
resulting in property damage, personal injury or death.

1. The CSA1 shall not be used on condensing heating equipment.

2. Gas-fired units without a draft hood / diverter must include a barometric draft regulator.

3. The CSA1 motor shaft must be mounted horizontally to prevent motor bearing wear.

4. The CSA1 shall not be installed where flue gas temperatures exceed 575

O

F (301°C) at the CSA1 inlet. Ambient room temperatures

must not exceed 104° F (40° C).

5. The installer must affix the wiring diagram label included with these instructions to the water heater casing adjacent to its rating plate.

6. The water heater may only be installed on the suction side of CSA1.

7. The installer must verify that the pilot safety controls on the water heater are in good operating condition before installation of the

water heater vent package.

8. The CSA1 must not be installed into any portion of a vent system which serves appliances other than the one vented by the CSA1.

9. Make certain the power source is adequate for the fan motor requirements. Do not add the CSA1 to a circuit where the total load is

unknown.

10. The installer must verify that the BTU/hr input of the water heater does not exceed the maximum input rating of the CSA1 (65,000 BTU/hr).

11. A safety inspection of the water heater must be performed before installation of the CSA1 as outlined in the International Fuel Gas

Code, (IFGC) Appendix D.

2

WITH THE ECO OF THE WATER HEATER.

REQUIRED. WIRE THE LINEAR LIMIT IN SERIES

THE THERMOCOUPLE JUNCTION ADAPTER IS NOT

ON 750 MILLIVOLT (POWER PILE) HEATERS

THERMOCOUPLE JUNCTION ADAPTER

PRESSURE TAP

FROM THERMOSTAT

6' LINEAR
LIMIT LEADS

115/1/60

SWITCH

GAS PRESSURE

GAS PRESSURE SWITCH

ALUMINUM TUBING TO

24" LONG 1/4" O.D.

LINE

GAS SUPPLY

BY OTHERS

WATER HEATER

BY OTHERS

THERMOSTAT

LINE

GAS PILOT

8050049 04/18/13

CLIPS

ROUTING

CABLE

THERMOSTAT CABLE

2 WIRE JACKETED

POWER CORD

SWITCH SET AT 185°F

SPILLAGE SENSING

LINEAR LIMIT

NEW GAS PRESSURE

TAP PORT LOCATION

NOTE:

CSA1

CAP ANY UNUSED

1/4 INCH PER FOOT

TOWARDS CHIMNEY

SLOPE UPWARD

- KEEP AWAY FROM
THE HOT FLUE PIPE

STACK OPENINGS

6 FOOT