SAFETY INTERLOCK TEST

IMPORTANT:
The Linear Limit Spillage Switch must disable the heater in the event of a venting malfunction. The following procedure is necessary to
confirm that the heater is disabled in the event of a venting malfunction that would cause the Linear Limit to trip and open its circuit.

1. Remove a Linear Limit Switch lead (black wire) from Thermocouple Junction Adapter or Thermopile ECO and verify the heater

pilot is extinguished.

2. Reconnect Linear Limit Switch lead removed in step 1 and re-light pilot following the water heater manufacturer’s instructions.

CSA1 WATER HEATER STACK ASSIST KIT LADDER WIRING DIAGRAM

DRAFT AND COMBUSTION AIR TEST

WARNING:
The Linear Limit Spillage Switch is designed to alert the user to a potentially hazardous condition. It is not designed to and
cannot replace regular vent system inspection, appliance servicing and combustion testing. DO NOT USE IT AS A SUBSTI-
TUTE FOR PROFESSIONAL APPLIANCE MAINTENANCE.

1. Close all doors and windows of the building. If the appliance is installed in a utility room or closet, close the entrance door. Close fire

place dampers.

2. Turn on clothes dryer. Turn on all exhaust fans, such as range hoods, bathroom exhaust and whole house fans to maximum speeds.

3. Following the water heater manufacturer’s instructions, place the appliance in operation, set thermostat for continuous operation.

4. Allow fans and appliance to operate for 5 minutes.

6

WHITE

BLACK

WHITE

BLACK

MOTOR

R1 RELAY

115 / 1 / 60 PLUG

YELLOW

RED

RED

BLUE

TRANSFORMER

115V

24V

THERMOCOUPLE

PRESSURE

SWITCH

GAS

JUNCTION ADAPTER

BLACK

BLACK

BLACK

LINEAR LIMIT

SPILLAGE SENSING SWITCH

(185°F MANUAL RESET)

COM

N / O

OR ECO OF WATER

HEATER

BLACK

7

8

R1 RELAY

TJERNLUND CSA1 (CHIMNEY STAC

K ASSIST)

ATTACH DIAGRAM ADJACENT TO WATER HEATER NAMEPLATE

1303310

BLACK

04/18/13

FIGURE 8075003

GREEN

DRAFT INDUCER

BLACK

WHITE

24V LOW VOLTAGE FACTORY WIRING

115V LINE VOLTAGE FACTORY WIRING

DENOTES HEATING APPLIANCE MILLIVOLT
CIRCUIT (THERMOCOUPLE OR ECO)

LEGEND:

DENOTES A QUICK CONNECT

DENOTES A WIRE NUT

6

4

GREEN

Advertising