Page (s)

Description and Specifications ....................................................................................................................................1, 2
Installation Restrictions .................................................................................................................................................2
Cautions .....................................................................................................................................................................2, 3
Safety Inspection of a Previously Used Gas Appliance ..................................................................................................3
SideShot

®

Model SS2G Terminology .............................................................................................................................3

Vent Hood Termination Clearances, Clearances to Combustibles & Obstructions ....................................................... 4
Installation

Tools Required .................................................................................................................................................5
Vent System Installation ..........................................................................................................................5, 6, 7
Installation of Vent Pipe ....................................................................................................................................7

Electrical Wiring

Wiring Restrictions ........................................................................................................................................7, 8
SS2G Wiring with Single Zone Thermostat.......................................................................................................8
Wiring to 24V Gas Valve ...............................................................................................................................8, 9
Draft Adjustment Procedure............................................................................................................................10

Combustion Air ............................................................................................................................................................. 10
Final System Operation Check Out ..............................................................................................................................10
Troubleshooting Electrical Problems .......................................................................................................................11, 12
Maintenance ..................................................................................................................................................................13
How to Obtain Service...................................................................................................................................................13
Warranty & Replacement Parts .....................................................................................................................................13
SS2G Vent Cabinet Mounting Template .......................................................................................................................14

SideShot

®

is a registered trademark of Tjernlund Products, Inc. for their Model SS2G Vent System.

DESCRIPTION

The SS2G is a mechanical vent system designed and listed for use with natural draft gas heating equipment. It is factory assem-
bled and wired. The SS2G automatically vents the flue gases from heating equipment to the outdoors. By recirculating indoor air
with a cooling fan, surrounding combustible materials remain at safe temperatures. After each burner cycle the SS2G will continue
to operate for a nonadjustable timed period of approximately 45 seconds to purge the heater and vent of residual flue gases. The
SS2G features a safety system consisting of a Fan Proving Switch and a High Limit temperature control. These devices monitor
the SS2G’s performance and will interrupt the main burner if a venting malfunction is detected.

APPLICATION TABLE

Verify that the total BTU/hr. input of the heating appliance(s) falls within the inputs listed below. The BTU/hr. capacity range is
based on a maximum of 50 equivalent feet. To determine equivalent feet, add the total length of straight vent pipe plus 10 feet for
each 90 degree elbow and 5 feet for each 45 degree elbow. Vent runs of over 15 linear feet require the use of an approved, insu-
lated vent connector to prevent problems related to condensation.

MODEL

Atmospheric

Natural & LP Gas

Fan Assisted

Natural & LP Gas

Max. Equivalent

Feet

SS2G

40,000-125,000 BTU/hr

40,000-150,000 BTU/hr

50

The SS2G Vent System may only be used on Natural or LP gas fired appliances.