9. After the SS2G is completely installed, apply a

bead of exterior rated caulk between the Vent
Hood Termination mounting flange and the
exterior of the building, (See Diagram G).

INSTALLATION OF WALL SUPPORT BRACKET

1. To prevent damage to the SS2G, temporarily support the bottom of the SS2G cabinet (prop on ladder top) while assembling the

wall support bracket. Assemble the wall support bracket as shown, (See Diagram H).

2. Connect mounting bracket to SS2G using (4) #8 x 3/8” sheet metal screws. Line up holes on bottom of SS2G with mounting

bracket to ensure proper placement, (See Diagram H).

3. Adjust the wall support bracket so that a slight pitch is maintained for moisture drainage and vibration isolation. Use the

prepunched holes on the wall bracket as a template to mark holes to be drilled into the side wall for mounting screws,
(See Diagram H).

4. a)

If installing the bracket into a wood wall, drill 2 pilot holes at each point established in step 3 with a 1/8" drill bit
approximately 1" deep and install the screws provided to secure the bracket to the wall.

b)

If installing the bracket into a masonry wall, drill 2 holes at each point established in step 3 with a 1/4" masonry drill bit
Tap the masonry anchors into the 2 holes drilled and screw the wall bracket onto the wall.

DIAGRAM H

8. Slide the SS2G vent cabinet through the wall with drip

flange facing down towards ground, (See Diagram F).
Mount Vent Hood to exterior using (6) #10 x 1 1/4”
wood screws provided, (See Diagram F). If installing
in masonry wall drill 1/4” holes and use wall anchors
provided.

IMPORTANT:
Adjust SS2G mounting
bracket for slight pitch.