DESCRIPTION

The Hot Shot™ Universal Stove Blower captures and distributes radiant heat from your stove that is otherwise wasted. The Hot Shot™
silently pushes room air between the "Heat Capture Chute" and the stove top, warming it along the way and then propelling it into the
room. Use the Directional Chute attachment and turning vanes to direct the warmed air left or right up to 45 degrees or straight to extend
Heat Capture Chute. Easy plug in electrical, installs without tools in minutes on most stoves.

SPECIFICATIONS

GENERAL INFORMATION

Each Hot Shot

TM

Stove Blower is factory tested before shipment. After opening carton, inspect thoroughly for shipment damage. Fan

should rotate freely and all electrical wires and connections should be secured. If any damage is found, notify freight carrier and your
distributor immediately and file a concealed damage claim.

INSTALLATION

The Stove Blower must be installed by a qualified installer in accordance with these instructions and all local codes or in their absence in
accordance with the latest editions of the International Residential Code and International Electrical Code. Improper installation can cre-
ate a hazardous condition such as fire, electric shock or personal injury. To reduce these risks significantly, use this unit only in the man-
ner intended by the manufacturer. If you have questions, contact Tjernlund Products. Always disconnect the Stove Blower from its
power source before installation and servicing

IMPORTANT: To protect the fan motor from excessive heat, mount with the blower assembly below and behind the heat shield of the
stove. Mounting in any different fashion voids the warranty. Using this product on a stove without a heat shield could result in property
damage and/or personal injury. Purchase Tjernlund part 950-9200 Heat Shield Kit to use this blower on a stove not equipped with
a heat shield.

CAUTION: The power cord can cause property damage and/or personal injury if not routed correctly away from the stove. The SB1
power cord must be routed away from any heat source.

Hot ShotUniversal Stove Blower

Model SB1

©2011 TJERNLUND PRODUCTS, INC. ALL RIGHTS RESERVED

P/N: 8504181

TJERNLUND PRODUCTS, INC.

1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • www.tjernlund.com

READ OWNERS INSTRUCTIONS CAREFULLY PRIOR TO INSTALLATION.

THESE INSTRUCTIONS MUST REMAIN WITH EQUIPMENT. DO NOT DESTROY.

Volts: 120

Hertz: 60

Watts: 25

Amps: 0.50 Max

CFM: 75

RPM: 1800

Sound: 42dB (1.15 Sones)