Page 36

THZ-100 T

HERMOSTAT

Troubleshooting Thermostat On-Screen
Notifications

There are notifications on screen for checking the filter, wireless.

If you receive a Check Filter notification then replace the furnace filter
and reset the filter notification as outlined above.

If you receive a Check Wireless notification then check the signal strength
of the THZ-100. If the strength is not excellent then
contact your dealer for more assistance.

If the display shows "Wait..." flashing during the operation of the HVAC system,
the Compression Protection has been activated. Once Compression Protection
cycles, the system can operate as normal. This will help prevent your
HVAC's compressor from turning ON and OFF too quickly.

If the THZ-100 shows a normal Idle state, but the current temperature is
outside the desired temperature, then the Maximum Cycles per hour have
been reached.

In addition, pairing to the MRX Advanced Network System Controller
base unit will be erased and the thermostat will need to go through the
discovery mode to re-establish communications.