Vintage Cellars Le Cache Cabinet Owners Manual User Manual

Page 8

Advertising
background image

L E C A C H E P R E M I U M W I N E C A B I N E T S

-7-

o

European Country and Mission wine cabinets can use our front-vent hood
without the decorative grill (the grill will not fit with crown moldings.)

• Please note: minimum clearance of 7 ½ inches above the wine cabinet is

required in order to remove the hood and air filter (ie periodic maintenance) for
the cooling unit.

Credenza wine cabinets don’t require clearance above the wine cabinet; however,
credenzas require 3-4" of space behind the wine cabinet because the ventilation (intake
and exhaust) occurs behind the cabinet.

If you received an air diverter with your credenza, use the magnets to place the diverter on
the back of the cooling unit (at the back of the credenza) so that the hot air exhaust is
directed to the left (when facing the credenza).


THERMAL LOADS AND COOLING CAPACITIES

We offer a choice of several cooling units, which should be selected based on the size of
the cabinet, the temperature in the ambient environment and the desired temperature
inside the wine cabinet, as follows:

Cooling Unit Capacity @ 55°F (1)

1800QTL

BTUH: 1065 Decibels: 42

1800QT

BTUH: 1380 Decibels: 45

1800XT

BTUH: 1456 Decibels: 48

Cabinet

Model

Credenza

1400

2400

3100

3800

5200

Ambient

Temperature

Thermal Load

70°F

640

640

729

833

927

1058

75°F

704

712

816

923

1049

1219

80°F

774

784

902

1013

1172

1380

85°F

857

856

989

1104

1294

X

90°F

930

930

1065

1183

1416

X

95°F

1002

1002

1136

1286

X

X

Advertising