Vintage Cellars Platinum Split Fully Ducted 4000WC User Manual
Page 19

www.whisperkool.com | Page 17
INSTALLING THE FULLY DUCTED EVAPORATOR (FAN COIL UNIT)
14. Connect the bottle probe to the circular connector located in the lower left side of the housing. Follow
the directions on page 14 for correct installation and placement of the bottle probe.
15. Install the supplied black strain relief to secure the power supply wires and bottle probe wire in the
housing.
16. Route the communication cable from the remote display into the evaporator housing
17. Connect the communication cable to the circular connector located in the lower left corner of the
housing.
18. If the unit was equipped with the Active Humidity Option, route the communication cable from the
desired control mounting location into the evaporator unit.
19. Connect the communication cable to the circular connector located in the lower left corner of the
housing.
20. Secure all wiring neatly and close to the left wall to minimize obstructing the airflow.
21. See page 12 for drain line routing instructions.
RUBBER WASHER
NUT
UNIT PANEL
CIRCULAR CONNECTOR/
BOTTLE PROBE INPUT
HOLE FOR CIRCULAR CONNECTOR
(BOTTLE PROBE INPUT)