Wine guardian, Humidifier “quick start” installation guide – Vintage Cellars Wine Guardian Humidifier Quick Start User Manual
Page 2
 
Wine Guardian
®
Humidifier
Integrated and Freestanding
Quick Start
Installation Guide
This document is a pictorial guide on installing the Wine Guardian hu-
midifier system. It is not intended to replace the detailed instructions 
found in the WG Humidifier Installation, Operation and Maintenance 
(IOM) manual, which includes important safety messages all WG in-
stallers and owners should carefully follow for safe and optimal per-
formance of the system. 
 
Refer to the IOM manual for installation instructions related to duct col-
lars and duct collar kits, optional remote interface control and remote 
sensors. 
 
 
 
 
Wine Guardian
®
Humidifier
“Quick Start” Installation Guide
6. Controller set-up instructions
A Locate the Wine Guardian remote
interface controller within the wine 
cellar or proceed to the Wine Guard-
ian Through-the-Wall (TTW) main 
control panel. (Fig. A & Fig. B) 
B Press the mode button and hold it
down for five (5) seconds. The screen 
will advance to the set up menu and 
“1 F” or “Setting # 1” will appear on 
the screen. (Fig. C & Fig. D) 
C Continue to press the mode button to
advance to setup screen “6 0” or 
“Setting # 6”. (Fig. E & F) 
D Press the up arrow to advance this
setting to either “1” for Freestanding 
Humidifier or “2” for Integrated Hu-
midifier (mounted at Wine Guardian 
Unit. (Fig. G & H) 
E Controller setup is complete. 
 
5. Installing Freestanding Humidi-
fier—with power cord and hu-
midistat 
A. Follow Step 3 (TTW or within
racking) or Step 4 (surface mount), 
A-H. 
B. Plug power adapter into 120 volt/1
phase/60 hertz receptacle. (Fig. A)
C. Mount independent humidistat
within wine room mid-point on 
wall or racking in an area that has 
sufficient access. (Fig. B) 
D. Refer to Humidistat Operations
Manual for additional information
E. Installation is complete. 
 
Visit www.wineguardian.com/distributors
Or call 800-825-3268 or 315-452-7400
 
 
 
Fig. A (TTW) Fig. B (Ducted)
Fig. C (TTW) Fig D (Ducted)
Fig. E (TTW) Fig. F (Ducted)
Fig. G (TTW) Fig. H (Ducted)
Photos to come
 
Air intake 
 
 
 
 
 
 
Air outlet 
 
 
 
 
 
 
 
 
Wall mount 
bracket 
 
 
 
Front access 
cover 
 
Access cover 
attachment screws 
Fig. A
Fig. B
Front of Unit—Freestanding
 
 Adapter plate 
 
Humidifier 
housing 
 
 
Humidifier pad 
Access cover 
 
 
 
Drain connection 
Power/control 
cable 
 
Back of Unit—Integrated
Mounting bracket
Through Wall Mount