 Size & Electrical Specifications
Model
Dimensions 
W” x D” x H” 
Weight
(lbs)
Operating
Amps
Required
Circuit
1800 QTL/QT/XT/XTS 18 x 16.5 x
10.5
60 3 15-Amp
Dedicated
1800 XTSx
18.1 x 22 x
10.6
70 3 15-Amp
Dedicated
 Ambient Environment
CellarPro cooling units are designed to operate in ambient temperatures between 
45°F and 95°F. Except for the 1800XTSx cooling unit, all cooling units are designed 
for internal use only, and are not designed for exposure to the exterior.
CellarPro cooling units are not designed to generate heat inside the cellar, so if 
temperatures inside the cellar drop below proper wine storage temperatures, the 
cooling unit cannot increase the temperature inside the cellar. 
Proper temperatures are maintained by transferring heat from inside wine cellars 
and exhausting heat through the top (top-vent) or rear (rear-vent) of the cooling units. 
 Insulation
CellarPro cooling units are designed to be installed inside wine cellars that have 
proper insulation, moisture barriers and an airtight seal from the environment 
outside the cellar.
Interior walls and floor 
should have a minimum of 
R-11 insulation, and a 
vapor barrier on the warm 
side of the insulation. The 
ceiling should have a 
minimum of R-19 insulation 
and a vapor barrier on the 
warm side of the insulation. 
Doors also should be 
insulated and tightly sealed 
with weather stripping 
around the perimeter of the 
door. Surface-mounted 
fixtures are recommended 
over recessed lighting, 
which can allow air to leak