Vintage Cellars 4200VSI CellarPro User Manual

Page 28

Advertising
background image


 

28

Alarms

The cooling unit has both an audible notification and a visual alarm indicator
(shown in “red” on the control panel) that are activated when an alarm is triggered.
Please note: the temperature alarms (HA, HA2, LA and LA2) are disabled during
the first 23 hours of operation after the cooling unit is plugged in and/or turned on.

The control panel also will flash a code for each alarm, as follows:

Alarm

Code

What it means

What to do

P1, P3

Probe Failure

Call CellarPro at 877.726.8496

HA

The temperature

inside the cellar is

too warm (above

70°F for more than 1

hour)

Check if the cellar has a leak

Check if door was left open

Lower the ambient temperatures

HA2 The

condenser

temperature is too high

(above 140°F for 2

hours)

Check for appropriate installation, ventilation,

ambient conditions and cooling capacity

Replace/Clean clean the condenser filter

Check for obstructions to the intake and/or
exhaust vents

Check that the condenser fan is operating

LA The

temperature

insidethe cellar is too

cold (below 45°F)

Raise the ambient temperature

Raise the “Minimum Set Point”

LA2

The temperature at the

condenser coils

(outside the cabinet)

has dropped below the

alarm temperature

setting

Lower the alarm temperature setting:

1. Depress the “Set” and “Down” button for

three seconds until the display reads
“HY”

2. Depress the “Set” and “Down” button for

seven seconds until “PR2” flashes on the
display

3. Using the “Down” button, scroll until the

display reads “AL2”

4. Depress the “Set” button and lower the

alarm temperature setting to your desired
setting