Vintage Cellars KoolR1800 User Manual

Warm side, Read before you start, Center

Advertising
background image

SUB-FLOOR

(STUD LUMBER)

CENTER

WARM SIDE

CENTER

WARM SIDE

1

2

3

4

5

6

WARM

SIDE

COOL

SIDE

!

!

FRAME

!

ELBOW

TUBE

CONT

AINER

SILICONE CAULKING

PLYWOOD

FLOOR VAPOR

BARRIER

INSULATION

(MIN. R-20)

SEAL ALL

JOINTS

ODORLE

SS

WATERP

ROOF

PAINT

DR

YW

ALL

VAPOR BARRIER

INSULATION

MINIMUM R-20

VAPOR BARRIER

Min. 6’

Min. 2’

c

lear

space

Min.5”

DR

YW

ALL

INSULATED

DOOR

WITH

AIRTIGHT

SEAL

ALTERNATIVE

WALL CUTOUT

RECOMMENDED

OVER THE DOOR

CUTOUT

Min

10”

1

2

3

4

5

6

Watch for live wires !

CAUTION!

LOCATION:

Appliance is for indoor use only. Never vent into a laun-

dry closet or similar room which traps warm air. Unit

must vent to an adjacent interior ventilated space close

to the ceiling. Exhaust air must not be obstructed in any

way.

TEMPERATURES:

Select a suitable area, sized to model’s cooling capacity,

where ambient temperature will not exceed the desired

storage temperature by more than 25ºF (14ºC). The

temperature of the air where the unit vents its warm air

must be at least 65ºF and never exceed 80ºF with 70%

R.H. Lower set temperature from default 57ºF (14ºC)

only if ambient condition allows.

Set temperature range: 52ºF - 64ºF (11ºC - 18ºC)

INSULATION:

Install unit where ALL surfaces (walls, floor and ceiling)

are insulated to R-20 and protected by vapor barrier on

both sides. Uninsulated concrete floors will radiate heat

and humidity during summer months, forcing the unit to

work inefficiently. All floors must be INSULATED! Use an

insulated door with weather seal.

POWER:

Outlet (on cool side) power must be a dedicated separate-

ly fused grounded 15-Amp 115 Volt line within reach of

supplied power cord (Europe; 10-Amp 220 Volt). Line

must not be shared. Do not use extension cords.

Electronics must be protected against sudden power

surges. Use a quality surge protector.

SPECIAL NOTE:

This unit is constructed for installation in walls up to 6

1/2” inches thick. If you install it in a thicker wall you will

have to cut out an area around the air vents on the cool

side in order to keep cool airflow unobstructed. Order

longer screws at www.koolrproducts.com.

READ BEFORE YOU START

• Center pattern to door frame.

• Trace pattern.

• Flip pattern and repeat for cool side.

• Cut out drywall, warm and cool side.

• Cut out Stud level to drywall cutout.

• Get help to insert cooling unit through hole.

• Guide cord, do not damage drywall!

• Slide over frame on cool side, guide cord

through frame side notch.

• Screw in cooling unit to frame.

• Place grill on unit.

WATER DRAIN
• Add tube to elbow.

• Insert elbow to cooling unit.

• NOTE: Excess condensation is caused by extreme

conditions. This is not required if your room is prop-

erly insulated.

ALTERNATE WALL CUTOUT
• Level pattern, trace both warm and cool side.

• Cut out drywall.

• Screw in cooling unit to frame.

MARK SLITS