CC SERIES
US Cellar Systems / 3070 Golden Ave, Long Beach, CA 90806 / www.uscellarsystems.com
(562) 513-3017 phone and fax / [email protected]
CC Cooling System Typical Installation
• Standard Line Sets should be 50’ or less.
Extended runs may require larger line
sizes and 3 oz of oil must be added for
every 10’ feet over 35’.
• Keep line sets as short as possible and
insulate.
• Excessive number of turns will cause
refrigerant flow problems. This could
cause early compressor failure. Suction
line accumulators are recommended.
Required if working lower than the
normal 55-65° operating range from
wine cellar.
• Drain line must always flow down hill to
drain or pump
• The system is controlled by a pump down
control system. There is no control wiring
between thermostat and condensing unit
• The line connections at Fan Coil and
Condensing Unit may not be the same as
the required line sizes
REFRIGERATION LINES
CEILING
W
ALL
W
ALL
CC FAN COIL
DRAIN LINE
RACKING
REFRIGERATION
LINES
CEILING
CONDENSING
UNIT
W
ALL
CC FAN COIL
RACKING
DRAIN LINE