Cc series – Vintage Cellars WS:SSCC8600TE User Manual

Page 3

Advertising
background image

CC SERIES

US Cellar Systems / 3070 Golden Ave, Long Beach, CA 90806 / www.uscellarsystems.com
(562) 513-3017 phone and fax / [email protected]

CC Cooling System Typical Installation

• Standard Line Sets should be 50’ or less.

Extended runs may require larger line
sizes and 3 oz of oil must be added for
every 10’ feet over 35’.

• Keep line sets as short as possible and

insulate.

• Excessive number of turns will cause

refrigerant flow problems. This could
cause early compressor failure. Suction
line accumulators are recommended.
Required if working lower than the
normal 55-65° operating range from
wine cellar.

• Drain line must always flow down hill to

drain or pump

• The system is controlled by a pump down

control system. There is no control wiring
between thermostat and condensing unit

• The line connections at Fan Coil and

Condensing Unit may not be the same as
the required line sizes

REFRIGERATION LINES

CEILING

W

ALL

W

ALL

CC FAN COIL

DRAIN LINE

RACKING

REFRIGERATION
LINES

CEILING

CONDENSING
UNIT

W

ALL

CC FAN COIL

RACKING

DRAIN LINE