RM Cooling System Typical Installation

• Keep line sets as short as possible.

• Excessive number of turns will

cause refrigerant flow problems.
This could cause early compressor
failure. Suction line accumulators are
recommended. Required if working
lower than the normal 55-65°
operating range from wine cellar

• Drain line must always flow downhill

to drain or pump

• The system is controlled by a pump

down control system. There is no
control wiring between thermostat
and condensing unit

• The line connections at Fan Coil and

Condensing Unit may not be the
same as the required line sizes

• Standard line sets should be 50’

or less. Extended runs may require
larger line sizes and 3oz. oil must be
added for every 10’ over 35’

REFRIGERATION LINES

CEILING

RACKING

RC FAN COIL

DRAIN LINE
LEAVE 2” ON EACH

SIDE AND BELOW

REFRIGERATION
LINES

CEILING

CONDENSING
UNIT

W

ALL

RACKING

DRAIN LINE

RC FAN COIL

W

ALL

W

ALL

(;7(5,25

9$325%$55,(5

,168/$7,21ದ

525%(77(5

,17(5,25

(;7(5,25

9$325%$55,(5

,168/$7,21ದ

525%(77(5

,17(5,25

Wall Construction

Ceiling Construction