4

7.

At the prompt type “Y” then press the ENTER key. Proceed following the Hyper terminal prompts and
change the channel address as required. The Local IP address must be unique for each module:

Module-1 Local

IP

198.9.200.221

Module-2 Local

IP

198.9.200.222

Module-3 Local

IP

198.9.200.223

Module-4 Local

IP

198.9.200.224

Module-5 Local

IP

198.9.200.225

Other addresses elements are common for all modules:
The Netmask:

255.255.255.0

for all modules

Default router:

198.9.200.1

for all modules

Local port:

1200

for all modules

Remote IP:

0.0.0.0

for all modules

Remote port:

0

for all modules

8.

With the above changes made, check that the read-back is correct and type “n” and then press ENTER.
HyperTerminal should report “Starting the main application”. Check that the Channel LED on the front
panel of the Fusion CCU is not illuminated.

9.

With the channel IP address now set, return the Configuration DIL switch for the channel to the up
position (OFF).

10.

Reset the channel configured by pressing the reset switch accessible through the small hole in the rear
panel.

Repeat the process for setting the IP address for any other channel.

Figure 1 Hyper terminal window

Important Note: ALWAYS ensure that the Configuration DIL switches are switched OFF (in the up
position) on completion of any changes to the channel configurations.