Operators guide

23

The Quickfix adaptor has a safety latch mechanism that is used to secure the head into position
on the Quickfix base.

Electrical connections

All of the pedestal’s main external ports are located on the VR power box at the South side of
the base, below the trim weight stowage slots [14] (see Fig. 1). Additional system configuration
ports are located on the VR control box at the North side of the base.

Power sockets

External mains power is connected to the power input connector [31].

The pedestal also has two power output sockets ([25], [26]).

The Head power output socket [25] supplies power to a Fusion head (for more
information consult the relevant Operators Guide). This socket is controlled by the
pedestal, it is switched [22], fused and isolated on activation of an emergency stop.

The auxiliary (Aux) power output socket [26] is protected by a system fuse, but is
permanently live and intended to supply non-moving auxiliary devices, such as
monitors.

Fig. 7 Vinten heavy-duty Quickfix adaptor safety latch

WARNING!
It is recommended to use a residual current device (RCD) to protect
personnel should the power cable become damaged.

WARNING!
DO NOT plug moving devices into the auxiliary (Aux) power port.
This port cannot be switched off at the pedestal and is not affected by
an emergency stop. Devices plugged into the auxiliary port must have
an independent isolator switch.

Safety