Wine-Mate SSR Series User Manual
Page 21
                                    Advertising
                                    
                                        
                                    
                                
                                 
- 20 -
BACK POSITION FRONT POSITION MIDDLE POSITION
Fig. 10Base Valve Operation
 
5. 
Checking Pressure Control Settings
1)
Use of the adjustable pressure control (if applicable for pump-down)
 
Suction pressure setting: Cut out=5 psig; Cut in=25 psig; Differential=20 psig 
Head pressure setting: Cut out=230 psig; Cut in=150 psig; Differential=80 psig 
It may need to adjust the setting in the field to get the right cycle time. 
 
A. P70 Single/Dual Control
B. PS2 Dual Control
Fig. 11 Adjustable Pressure Control