Fig. 7 Temperature Controller (4.25”L X 3.75D X 4.25”H)

2. Temperature Controller and Air Probe Installation

1) The temperature controller can be mounted either inside or outside the wine

cellar, but the air probe must be located inside the wine cellar or the return
duct.

2) The air probe shall be located in the wine cellar 5 ft above the floor or the air

return area, but it shall not be located in the air supply area or other areas
where air is not circulated.

3) Air probe can be pulled out of the temperature controller around 5 ft; if

additional wires are needed, 18 gauge wires may be used to extend the air
probe.

4) If the air probe is installed in a return duct, the evaporator fans shall be

running all the time. Meanwhile due to the temperature differential the
temperature, air probe calibration should be used in order to maintain the
proper wine cellar temperature.

3. Evaporator Unit Installation

1) WM-25~85SFCH evaporator units can be installed outside a wine cellar. It

shall not be exposed to temperatures higher than 85 °F.

2) Air supply shall be unobstructed minimum 12” for a direct blow installation;

leave 2” clearance for a deflector installation; air return shall be unobstructed
minimum 6”.

3) Secure the ducts with conduits to the cellar exterior walls and make sure they

are not curled, twisted, bent and clogged.

Model No

Insulated

Duct

WM-2500SSHWC 8”
WM-4500SSHWC 8”
WM-6500SSHWC 10”
WM-8500SSHWC 10”

Advertising