SECTION VIII: ELECTRICAL CONNECTIONS

WARNING

Turn off or disconnect the electrical power supply to the water heater before servicing. Label all wires prior to
disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Verify proper
operation after servicing.
All electrical wiring must be installed and grounded in accordance with local codes, or in the absence of local
codes, the National Electrical Code, ANSI/NFPA 70 and/or CSA C22.2 Electrical Code.


The water heater must be wired to a 120 VAC, 60 Hz, 15A power supply. The water heater must be wired on a
separate circuit and breaker. If a flexible line cord and plug is permitted by local code, then provide a three wire
grounding type receptacle within reach of the line cord provided on the control box. Do not plug the line cord into a
receptacle that can have the power supply interrupted by a switch that is used to control lights or another appliance.

If wiring in conduit is required, cut the line cord close to the control board and make the appropriate wiring connections.
Install an electrical conduit connector on the outside jacket of the water heater. Refer to the wiring diagram for the
correct connections to each wire lead.

CAUTION

This water heater must be wired on a separate circuit. Failure to wire on a separate circuit may cause
improper operation or failure of the electrical components of the water heater. Refer to the “Electrical
Connections” section of the Installation and Operating Instructions Manual for complete instructions on
electrical wiring and connections to the water heater.
Do not energize the electric circuit before the water heater tank is filled with water.

Figure 25. Wiring Diagram and Schematic

LINE IN

PRIMARY

SECONDARY

CONTROL

E-COM

1

2

3

E-COM

1

3

2

SENSE

SENSOR 1

9

8

7

6

5

4

3

2

1

1

2

1

2

3

4

1

2

3

3

2

1

120 VOLTS AC

LINE

LOAD

24V

1

2

3

M

COMBUSTION

BLOWER

PV/MV

MV

GAS VALVE

LOWER

SENSOR

& ECO

6 PIN CONNECTOR

TO PRESSURE

SWITCH HARNESS

IF ANY OF THE ORIGINAL WIRES AS SUPPLIED WITH THE APPLIANCE

105°C WIRE OR ITS EQUIVALENT.

MUST BE REPLACED. IT MUST BE REPLACED WITH 18. GA STRANDED

SI UN DES CONDUCTEURS D'ORIGINE FOURNI AVEC L'APPAREIL DOIT

NOTE:

CONNECTION DIAGRAM

WIRING DIAGRAM

CONTROL

DISPLAY

TRANSFORMER

120V

HIGH VOLTAGE

SPARK

120V

24V

24V

24V

120 VAC

BLACK

120 VOLTS

120 VOLTS

24 V.

WHITE

GROUND

INDUCER

4

1

5

2

6

3

BK

R

W

R

O

BL

BR

W

BK

W

BL

W

GN

BK

Y

W

R

W

Y

M

DISPLAY

HIGH VOLTAGE

SPARK

SENSE

R

R

MV

GAS VALVE

M

BLOWER RELAY COIL

W

O

PV

(BOARD CIRCUIT)

5

2

P.S.

BLOWER RELAY

BLOWER MOTOR

GN

GN

R

R GY

GY

NC

COLLECTOR

LIMIT

ECO

TSTAT

G

GND

N

L1

SWITCH

LIGHT

ANODE RODS

(399,999 BTU/HR MODELS ONLY)

ETRE REMPLACE UTILISER UN CONDUCTEUR 18 GA STRANDED 105°C
OU L'EQUIVALENT.

GY

R

R

GY

GY

P.S. (N.C.)

COLL HIGH-LIMIT
LIMIT (N.C.)

CONTROL BOARD

BK

TOGGLE

Advertising
This manual is related to the following products: