ACCESSING SERVICE MODE ON THE WATER HEATER DISPLAY (FOR SERVICE
PERSONNEL ONLY)

The display has a “Service Mode” for changing the maximum setpoint and accessing information in aiding servicing of
the water heater. This procedure is for service and installation personnel only. To enter the Service Mode, follow the
steps illustrated below:

WARNING

The following procedure is for service and installation personnel only. Resetting lockout conditions
without correcting the malfunction can result in a hazardous condition.


Step 1: Press “Select” and “Temperature Up” buttons together and hold for 3 seconds until “Max Setpoint” is shown in
the display.

NOTICE

30 Seconds after the last button press, the display will automatically return to the “User Mode”.
Simultaneously pressing the “Select” and “Temperature Up” buttons will switch the display immediately to
the “User Mode”.


Step 2: Pressing “Select” button will change display to next mode

SELECT

SET

Status

idle

Operational

"Max Setpoint"

next to Temperature

Setpoint value.

Max

Setpoint

°F

SELECT

SET

Status

°F

idle

Operational

Water

Temp

Advertising