SecureLinx POE Protectors: Wiring Conventions

• Shall be wired per TIA/EIA 568A or 568B. • Power Pairs: Blue, Brown (Clamp at 62V).

• Data Pairs: Orange, Green (Clamp at 16V).

Figure 1

C.) SecureLinx MTC-TL1. See Figure 5.

The SecureLinx MTC-TL1 is designed to protect the low voltage lines for traffic control systems,

PTZ Cameras and other remote equipment and begins clamping at 7.5 volts. It also protects a

2-wire telephone line and begins clamping at 220 volts. The ground terminal should not be used

unless the wiring is done with shielded wire. In that case, connect the shields to the “GND”

terminals on the module.

1. Strip back the outer jackets of both the Signal and Telephone wires about 4 inches (See figure 5).

2. Strip the ends of the individual wires about 1/4 inch. The MTC-TL1 has special screw clamp

terminals that work with a range of wire sizes without lugs or tinning wires (See figure 3).

3. Connect the ground wire or shield wire to the “GND” terminal on the “Protected” side of the

module.

4. Connect the wires from the traffic signal controller to terminals 1-2, 4-5, 7-8 on the “Protected”

side of the module. Connect the telephone wires from the Central Office (CO) to terminals 9-10

on the “Protected” side of the module.

5. Connect the wires to the traffic signal equipment (lights) to terminals 1-2, 4-5, 7-8 on the

“Unprotected” side of the module. Connect the telephone wires from the modem to terminals

9-10 on the “Unprotected” side of the module.

6. Mount protector to a solid surface, like plywood. Drill a 3/32 hole for the #6 x 3/4 screw and

eyelets provided. (See figure 4). Attach screw and eyelet to wall and slide protector over screw

and tighten. Add second screw to bottom of protector.

Eyelet

#6 Screw

Side

View

Of

Wall

Eyelet W/screw

L

E

N

I

GND

U
I
P

E

M

T

N

Q

E

N
E

L
I

E

M

T

N

U
I

Q

P

E

GND

Isolated Loop Ground
Use 14 AWG Wire

Primary Protector Good Earth Ground

See #9 and #10 above for ground wire size

See #10 above, tighten the bonding screws
Additional protector bonded together

E

Q

U

I

P

M

E

N

T

L

I

N

E

Figure 2

Figure 3

Figure 4

Figure 5

SecureLinx CAT5

SecureLinx CAT6

MTC-TL1

www.itwlinx.com • 425 North Gary Ave., Carol Stream, IL 60188

For technical support, please call

1-800-336-5469

Printed in the U.S.A.

Part#: 2500-936-30I Rev. 2-09/2010

D). Power Up!

After all the modules and base units have been properly installed and connected, turn on the

power to the SecureLinx unit and then the protected equipment. You’re Done!

PATENTED: 6134093, 5841620