Table 78: example selection of sense bytes – Ciprico Rimfire 3880 User Manual

Page 147

Advertising
background image

User’s Guide

21020285 D

Chapter 7 Board-control Commands

Unit Options (08H)

Page 7 - 23

If the Sense Count field is set to 0, but there are non-zero values in the Selected
Sense bytes fields, the byte numbers and order you define in the Selected Sense
Bytes fields are used to return automatic Request Sense information for this
device.

Example Use of Selected Sense Bytes Fields

In this example your device has valuable information, in bytes other than the
first eight, that you wish to substitute:

Byte 12 is an Additional Sense Code.

Bytes 15 through 17 include additional error information.

Assume bytes 16 and 17 are pointers that you wish to read in as a word. You
will arrange them in the group of Sense Bytes to make this easy. For the
example, the Sense Count field must be set to zero. The Selected Sense Bytes
fields of the Unit Options command would look like this:

Address

Offset

Byte Memory Address

Offset + 0

Offset + 1

Offset + 2

Offset + 3

00H

Command Identifier

04H

Disconnect Time-out

Unit SCSI ID

Adapter ID = FFH

08H

Select Time-out

Retry Control

Retry Limit

0CH

Reserved

Reserved

Sense Count = 0

Unit Flags

10H

Command = 08H

Reserved

14H

0H (Class/Code)

01H (Segment)

02H (SCSI Flags)

03H (Info Byte)

18H

0CH (Byte 12)

0FH (Byte 15)

11H (Byte 17)

10H (Byte 16)

Table 78: Example Selection of Sense Bytes