Parts replacement, Caution – Nexen 5H70PSP 914000 User Manual

Page 10

Advertising
background image

10

FORM NO. L-20060-U-1209

ParTS rePlaCeMenT

Set Screw

(Item 20)

retaining

ring (Item 14)

FIGure 2

Set Screw

Collar (Item 25)

Drive Flange

assembly

Hub

(Item 1)

a. DISaSSeMBly.

refer to Figures 2-4.

1. Remove all Set Screws (Item 20). On Models 5H70P-

SP” and "5H80P-SP" the Set Screw Collar (Item 25)
must be removed also.

2. Remove Retaining Ring (Item 14).

3. Press Hub (Item 1) out of Drive Flange.

nOTe: If a press is not available, use a bearing

puller to remove Drive Flange assembly

from Hub.

4. Remove Backing Plate (Item 7).

nOTe: Backing Plate is initially assembled with 680

loctite

®

. a bearing puller may be required

to remove it.

5. Remove Springs (Item 8).

6. Separate Cylinder ((Item 2), Drive Ring, and Bearing

(Item 11) from the Hub (Item 1), Piston (Item 3), and
Piston Bearing (Item 12).

7. At this point, if bearings are not being replaced, O-Rings

(Items 15 & 16) can be replaced and the Hub Spline
can be relubricated without further disassembly.

a. Coat O-Ring surfaces of Piston (Item 3) and Cylinder

(Item 2) with a thin film of O-Ring lubricant.

b. Coat O-Ring (Items 15 & 16) with a thin film of

O-Ring lubricant.

c. Install new O-Rings.

d. Coat Hub Spline Teeth with ‘Never-Seez”

®

.

nOTe: If bearings are not being replaced, go to

"Paragraph C, reaSSeMBly".

FIGure 3

Backing Plate

(Item 7)

Spring

(Item 8)

FIGure 4

O-ring

(Item 16)

O-ring

(Item 15)

Cylinder

assembly

lubricate Spline

with

"never-Seez"

®

Piston and

Hub assembly

CAUTION

Working with spring loaded or tension
loaded fasteners and devices can cause
injury. Wear safety glasses and take the
appropriate safety precautions.

Advertising