CAUTION

Rigid pipe or tubing when connected directly
to the clutch will prevent proper actuation of
the clutch. Use flexible hose or tubing when
making air line connections to the clutch.

nOTe

For quick response, nexen recommends a quick exhaust

valve and short air lines between the Control Valves and

the product. align the air inlet ports to a down position

to allow condensation to drain out of the air chambers

of the product.

CAUTION

Low air pressure will cause slippage and

overheating. Excessive air pressure will

cause abrupt starts and stops, reducing

product life.

All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.

The following is a common air supply scheme used with
this product. This is an example and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.

aIr COnneCTIOnS (continued)

OPeraTIOn

WARNING

Never exceed maximum operating
speeds listed for your product.
(See Table 5).

CAUTION

The temperature limits for this
product line are 4.5-100 Degree
Celsius (40-220 Degree F).

TaBle 5

Size

Max rPM

5H30PSP

3700

5H35PSP

3200

5H40PSP

3000

5H45PSP

3000

5H50PSP

3000

5H60PSP

2400

5H70PSP

2000

5H80PSP

2000

WARNING

Ensure proper guarding of the product is

used. Nexen recommends the machine builder

design guarding in compliance with OSHA 29

CFR 1910 “Occupational Safety and Health

Hazards”.