Nexen 5H70PSP 914000 User Manual
Page 8
8
FORM NO. L-20060-U-1209
CAUTION
Rigid pipe or tubing when connected directly
to the clutch will prevent proper actuation of
the clutch. Use flexible hose or tubing when
making air line connections to the clutch.
nOTe
For quick response, nexen recommends a quick exhaust
valve and short air lines between the Control Valves and
the product. align the air inlet ports to a down position
to allow condensation to drain out of the air chambers
of the product.
CAUTION
Low air pressure will cause slippage and
overheating. Excessive air pressure will
cause abrupt starts and stops, reducing
product life.
All Nexen pneumatically actuated devices require clean
and dry air, which meet or exceeds ISO 8573.1:2001
Class 4.4.3 quality.
The following is a common air supply scheme used with
this product. This is an example and not an all-inclusive
list. All air circuits to be used with this product must be
designed following EN983 guidelines.
aIr COnneCTIOnS (continued)
OPeraTIOn
WARNING
Never exceed maximum operating
speeds listed for your product.
(See Table 5).
CAUTION
The temperature limits for this
product line are 4.5-100 Degree
Celsius (40-220 Degree F).
TaBle 5
Size
Max rPM
5H30PSP
3700
5H35PSP
3200
5H40PSP
3000
5H45PSP
3000
5H50PSP
3000
5H60PSP
2400
5H70PSP
2000
5H80PSP
2000
WARNING
Ensure proper guarding of the product is
used. Nexen recommends the machine builder
design guarding in compliance with OSHA 29
CFR 1910 “Occupational Safety and Health
Hazards”.