Step, Fence transmitter indicator light status table, 7a 7b – Petsafe YardMax™ Rechargeable In-Ground Fence™ User Manual

Page 17: 7d 7c

Advertising
background image

www.petsafe.net 17

13. Turn the Fence Transmitter ON. The Indicator Light on the Transmitter should illuminate to green indicating a

properly installed boundary loop. If the alarm sounds and Warning Light illuminates red, check the connections

to make sure there isn’t an open circuit. If still not operating correctly, refer to the “Troubleshooting” section in

this guide.

Fence Transmitter Indicator Light Status Table

Status Light

Condition

Solid Green

Power On

Red

Boundary Wire Broken/Disconnected

None

Transmitter is OFF or Power is Disconnected

Verifying Transmitter Boundary Wire

Connection using Receiver Collar

With the Boundary Wire in place and properly connected and the Receiver Collar fully charged, it is time to test the

system. This step needs to be completed for both YardMax

®

and Traditional Modes.

• The Receiver Collar should NOT be on your dog when the system is tested. Your pet may receive an

unintended correction.

• To prevent an unintended correction for your pet, test the boundary location and width after any change.

Testing the system ensures you have signals in proper direction to contain your pet. If wire is reversed, go back

to Fence Transmitter and swap the wires going into red and black connectors.
1. Power the Fence Transmitter ON.
2. Set Fence Transmitter Mode (A/B) Switch to A

(YardMax

®

mode)

3. Set the Boundary Width Dial on the Fence

Transmitter to 3.

Note: The numbers on the Transmitter

Boundary Width Dial indicate signal strength

and not a boundary width measurement.

4. Select a section of straight Boundary Wire that

is at least 50 feet long.

5. Set Receiver Collar to Correction Level 6 (refer

to Step 3).

6. Place the Test Light Tool Contacts on the

Contact Points of the Receiver Collar (7A, 7B).

Test Light Contacts

7A

7B

7. Hold the Receiver Collar with the Contact Points

pointing up (7C) on the receiver facing the Boundary

Wire.

8. Start inside the Pet Area approximately 5 feet from

the Boundary Wire. Test the Boundary by approaching

and crossing the boundary wire as shown (7D). As you

cross the wire, you will hear the Warning Tone and see

the test light flash as you continue to walk further. If

you don’t hear the warning tone, turn around and walk

back across the Boundary Wire into the Pet Area to see

if it tones in that direction as the wire may be reversed.

If so, reverse the wires at the connector to the Fence

Transmitter. Do not adjust the wires connected to the

Boundary

Wire

7D

7C

Surge Protector. Then, repeat the test.

9. After verifying Receiver Collar operation at the boundary, use the labels

(7E) to identify the wire connections to the Fence Transmitter and the

Surge Protector. This will be convenient to have should any of the wires

become disconnected.

Red

Black

Loop Right

Loop Left

TX Left

TX Right

402-027

Red

Black

Loop Right

Loop Left

TX Left

TX Right

After verifying Receiver Collar

operation at the boundary, use the

labels to identify the Boundary Wire

connections to the Transmitter and

the Boundary Wire connections

to the Surge Protector. This will be

convenient to have should any of the

wires become disconnected.

Use on

Transmitter

Connections

Use on

Surge

Protector

Connections

7E

Step

7

Advertising