Maintenance – Ryobi RY60520 User Manual

Page 16

Advertising
background image

16

MAiNTENANcE

To replace the spark arrestor:

Remove the five screws that hold th

e muffler.

NOTE: Removing these screws requires the use of a T0
and T5 torx screwdriver.

Remove the muffler assembly and muffler gasket. It may
be necessary to work the muffler assembly free from the
muffler gasket.

Remove the three screws that hold the plates on the
muffler.

Remove the spark arrestor.

Replace the old spark arrestor with the new one.

Reassemble the muffler by reinstalling the plates and
tightening the three screws.

Reassemble the muffler and attach to the muffler gasket
with the two screws.

Reinsert the m

uffler assembly and fasten with the five

screws.

Reinstall the cover on the tool.

NOTE: Do not overtighten s

crews.

REPLAciNG THE SPARK PLUG

See Figure 20.
The cultivator uses a Champion RZ7C spark plug. Use an
exact replacement and replace annually.

Remove the spark plug boot.

Loosen the spark plug by turning it counterclockwise with
a socket.

Remove the spark plug.

Hand thread the new spark plug, turning it clockwise.

Tighten with a socket and torque to 170 in. lb. minimum,
190 in. lb. maximum. Do not overtighten.

cAUTiON

Be careful not to cross-thread the spark plug. Cross-
threading will seriously damage the product.

SPARK

PLUG

Fig. 1

SPARK

ARRESTOR

PLATE

MUFFLER

GASKET

SCREW(S)

SCREW(S)

COVER

SCREW(S)

MUFFLER

REPLAciNG THE SPARK ARRESTOR

See Figure 21.
The muffler is equipped with a spark arrestor screen inside
muffler body. After extended use the screen can become dirty
and may need to be replaced. If replacement is necessary,
use part number 00099816.

WARNiNG:

To avoid a fire hazard, never run the cultivator without the
spark arrestor in place.

Fig. 0

Advertising