Configuration level items, Parameter level items, User level items – Beckett RWF40 Hints Manual User Manual

Page 14: 2 your record of values

Advertising
background image

13/16 CC1B-Hints-en

Preliminary

04.02.2003 HVAC Products

3. Notes

3.2 Your record of values

RWF40

Setpoint

Your

Man. Ref.

Display

Setting

Configuration level items

( Sec 6.4 )

Range

Factory

Sec 8.1

C111

Analog input 1, 2 and 3;D2 setpoint changeover / shift

N /A

9030

Sec 8.1 / 8.2

C112

Limit comparator; controller type; setpoint 1; locking

N /A

0010

Sec 8.1

C113

Unit address; decimal place / unit, signal for out-of-range

N /A

0110

Sec 8.3.1

SCL

SC

ale

L

ow, analog input 1, measured value range

-1999 to +9999

0

Sec 8.3.2

SCH

SC

ale

H

igh, analog input 1, measured value range

-1999 to +9999

100

Sec 8.3.3

SCL2

SC

ale

L

ow, analog input

2

, measured value range

-1999 to +9999

0

Sec 8.3.4

SCH2

SC

ale

H

igh, analog input

2

, measured value range

-1999 to +9999

100

Sec 8.3.5

SPL

S

et

P

oint

L

ow limit

-1999 to +9999

0

Sec 8.3.6

SPH

S

et

P

oint

H

igh limit

-1999 to +9999

100

Sec 8.3.7

OFF1

OFF

set analog input

1

, Actual value correction

-1999 to +9999

0

Sec 8.3.8

OFF2

OFF

set analog input

2

, Actual value correction

-1999 to +9999

0

Sec 8.3.9

OFF3

OFF

set analog input

3

, Actual value correction

-1999 to +9999

0

Sec 8.3.10

dF1

d

igital

F

ilter, analog input

1,

2

nd

order, in seconds

0 to 100

1

Setpoint

Your

Display

Setting

Configuration level items

, Modbus option (only RWF40.0X2B97)

( Sec 6.4 )

Range

Factory

Sec 8.3.11

dF3

Filter time constant,

d

igital

F

ilter, analog input

3

weather-dependent setpoint shift

0 to 1440

1278

Sec 8.3.12

oLLo

W

o

rking range,

L

imit

Lo

wer

-1999 to +9999

-1999

Sec 8.3.13

oLHi

W

o

rking range,

L

imit

Hi

gh

-1999 to +9999

9999

Sec 8.3.14

Dtt

Bus wa

t

ch

D

og

t

imer (in seconds)

0 to 7200

30

Setpoint

Your

Display

Setting

Parameter level items

( Sec 6.3 )

Range

Factory

Sec 7 / 8.2

AL

A

larm value for K6

L

imit comparator (alarm programmable relay)

-1999 to +9999

0

Sec 7 / 8.2

HYSt

Hyst

eresis, (switching differential) for K6 limit comparator

0 to 999.9

1

Sec 7 / 8.2

Pb.1

P

roportional

b

and

1

(affects P-response of controller)

0.1 to 999.9

10

Sec 7 / 8.2

dt

d

erivative

t

ime (in seconds) (affects D-response of controller)

0 to 9999

80

Sec 7 / 8.2

rt

Integ

r

al action

t

ime (in seconds) , (affects I-response of controller)

0 to 9999

350

Sec 7 / 8.2

db

*

d

ead

b

and, contact spacing, * visible when C112 is xxx0, 3-pos modulating

0 to 999.9

1

Sec 7 / 8.2

tt

*

Ac

t

uator running

t

ime (in seconds) , * visible when C112 is xxx0, 3-pos modulating

10 to 3000

15

Sec 7 / 5.51

HYS1

Switch-on threshold,

HYS

teresis

1

, 2-stage burner

0 to -199.9

-5

Sec 7 / 5.2

HYS2

Switch-off threshold,

HYS

teresis

2

, 2-stage burner

0 to HYS3

3

Sec 7 / 5.2

HYS3

Switch-off threshold,

HYS

teresis

3

, upper

0 to 999.9

5

Sec 7 / 5.6

q

Response threshold (

Q

)

0 to 999.9

0

Sec 7 / 5.51

H

H

eating curve slope

0 to 4

1

Sec 7 / 5.5

P

P

arallel displacement (weather dependent setpoint shift)

-90 to +90

0

Setpoint

Your

Display

Setting

User level items

( Sec 6.2.1 )

Range

Factory

Sec 6.2.1

SP1

S

et

P

oint

1

SPL to SPH

0

Sec 6.2.1

SP2

S

et

P

oint

2

, digital input 2, D2=0

SPL to SPH

0

Sec 6.2.1

dSP

d

igital

S

et

P

oint shift, digital input 2, D2=1

SPL to SPH

0

Sec 11.1.3

tA

t

emperature,

A

mbient (outside) analog input 3, visible when C111 is xx1x, xx2x, xx3x

--

Sec 11.1.2

SP.E

S

et

P

oint

E

xternal, predefinition, analog input 2, visible when C111 is xx1x, xx2x, xx3x

SPL to SPH

--