Table 5. system alarm option definitions -11 – CANOGA PERKINS 2461 E1 Modem User Manual

Page 41

Advertising
background image

EdgeAccess Universal Chassis System

Table 5: System Alarm Option Definitions

Alarm Name

Condition

Notification

LED

Modem Redundancy

Status

Reports the status of

the Remote and Local,

Primary and Secondary

Modems.

Active, Inactive and N/A

None

Configuration Errors

Fiber connection error,

remote partner error,

(see CFG LED error

list in section 3.1.1)

OS, OLIM type, OLIM slot, ELIM type,

ELIM slot, Fiber line Setup (see the note

at the bottom of this table)

CFG

Fiber Loss of Signal

Composite (fiber) loss

of sync

No, Yes

LOS

Electrical Loss of

Signal

Loss of signal to the

ELIM

No, Yes

LOS

Alarm Indication

Signal

Receiving AIS

OK

AIS

on

ELIM

Link Self Test Status

The auxiliary BERT

(which is always

running) is out of sync.

OK, Bad, and NA (NA indicates

composite loss of sync)

TST

SQL Primary

Indicates inadequate

signal quality through

fiber. A possible

indicator of poor

quality fiber.

OK, Bad

SQL

on

OLIM

Optical Transmit

Level

Certain OLIMs allow

monitoring of

transmission power

(light level). Indicates

condition of optic

signal.

OK, Bad, or NA, if OLIM that supports

this feature is not present.

SQL Secondary

Indicates condition of

optic signal in

secondary (redundant)

OLIM.

OK, Bad, NA

Chassis Management

Indicates presence of an

operative DMM

anywhere in the domain

(even in a different

chassis).

OK: A functioning DMM is present
OFF: No DMM is present
BAD: The Proprietary Chassis Link, or
the DMM itself is not
functioning properly

2461 Modem User Manual