1 swapping software versions and resetting, 2 copying the software upgrade to other modems – CANOGA PERKINS 2461 E1 Modem User Manual

Page 70

Advertising
background image

EdgeAccess Universal Chassis System

4. Type "3." The TFTP Operation Screen appears.

5. Enter the TFTP Server IP Address.

• Use the default IP address or
• Follow the on-screen prompts for saving the IP Address as the default.

6. Enter the filename, for example

• 2X6X0173.zip. for firmware
• 2X6X0115.bin for bootcode

Note: The last three digits of the filename indicate the version number. For example,
2X6X0173.zip indicates firmware version number 1.73 is to be downloaded. Also,
2X6X0115.bin indicates bootcode version 1.15 is to be downloaded.

1. Follow the on-screen prompts for downloading the file.
2. "Download in progress, please wait,' is displayed momentarily.

CAUTION: Make sure the unit is not reset or powered down at this time. A
loss of power while the new code is moved to flash could result in loss of
bootcode. The unit would then have to be returned to the factory for
replacement of the bootcode.

8.3.2.1 Swapping Software Versions and Resetting

1. Once Download is complete, the new version resides in the inactive flash memory region. To

make it operational, it must be swapped with the active region. If you are still viewing the
TFTP Operation Screen, press Enter to return to the Software Upgrade Screen.

2. To Swap software versions, type "2." The Swap Bank option will be highlighted. Press Enter

3. Modem will reboot, then go online with the new software now active. The inactive flash

memory region contains the old version. It can be swapped back (again made active), should
a problem occur.


After swapping software versions, the older version now resides in the inactive flash memory
bank. If the module displays unexpected behavior using the newer revision, or the upgrade
became somehow corrupted, just swap the two memory banks again, and the module can quickly
be brought back online using the previous software version.

8.3.2.2 Copying the Software Upgrade to Other Modems

With the DMM, software revisions can be simultaneously uploaded to every modem requiring it.
You need not upgrade each modem one at a time. Stand alone modem pairs sharing data with a
chassis-based modem can be upgraded in a single session. When TFTP is used, all modems in a
link are simultaneously upgraded.

1. To copy the new software version to other modules, from the Software Upgrade screen,

type "4."

2. To upload the new software to other modules, follow the on-screen prompts.

2461 Modem User Manual

8-4

Advertising