Table 6 describes the function of each trap:

Table 6: Alarm Trap option definitions

Name

Function

1. All Traps

Enables or disables all the traps in this list

2 Inactive Link/Modem Traps

Loss of signal received from attached
equipment

3 Electrical AIS

"All 1's" signal pattern received from attached
equipment

4 Configuration

Incompatibility between local and remote
modem, or between main modem module and
the LIMs attached to it

5 Power Supply

Failure of power supply in the remote chassis

6 Test

Failure of Bit Error Rate Test (BERT) or failure
in the continuous self-test operation

7 Link Self Test

Failure of fiber between Local and Remote units

8 Power On Self Test

Failure of Power-On self test

9 Inactive Composite Link

In a redundant configuration, failure of the
redundant or inactive link .

4.4.7 Stand Alone Modem: Alarm Input Settings

The stand alone modem allows inputting of alarms from an external device, thus generating a
trap, (if the trap is enabled) when triggered. To enable this feature:

1. From the Main Menu, type "1" to open the System Configuration screen.
2. Type "3," Link Level Trap Configuration.
3. Look at option 8. If Alarm Input Trap is enabled, the feature is enabled.
4. If Alarm Input Trap is "disabled", type "8," then press the spacebar to "enable" the option.