2. Record the numbers for the Active and Inactive Firmware for both the local and remote modems.

3. Access the Canoga Perkins Web site, click Downloads, scroll to the 2370 file name and compare

the version numbers listed there with the version numbers you recorded. The 2370 firmware file
name is similar to

23x00106.zip

, where

23x0

indicates the product type and

0106

indicates

the version number.

Caution:

To ensure compatibility when two or more units are connected, you must upgrade all
connected units with the same software.

If the firmware on the 2370 is outdated, you need to upgrade it. If the 2370 is in a chassis or
standalone enclosure within a domain with a DMM, go to the User Manual for the DMM and use that
procedure to install the new software. If the 2370 is in a Model 1040, follow these steps:

1. Access the SNMP Configuration menu before starting the software upgrade: enter the IP address,

subnet Mask, and default gateway for the SNMP agent.

2. From the Main Menu, type

7

, Upgrade Software, and press <Enter>.

3. At the Software Upgrade menu, type

4

, Get New File with TFTP, and press <Enter>.

4. At the prompt, type the IP address for the source of the software.

5. At the prompt, type

Y

to confirm the choice.

6. If the file name differs from the default, type it and press <Enter> or press <Enter> to accept the

default.

7. At the prompt, type

Y

to start the upgrade.

To upgrade a remote unit to the same version of software, follow these steps:

1. Make sure that the remote modem is online.

2. From the Main Menu, type

7

, Upgrade Software, and press <Enter>.

3. At the Software Upgrade menu, type

3

, Copy Software from Source modem to Destination

modem, and press <Enter>.

4. At the prompt, select the Source modem, then the Destination modem, and press <Enter>; the

upgrade runs automatically.

To run the new software, swap banks, and reset the modem, follow these steps:

1. Check the version of the Inactive Firmware for the Remote modem to be sure that the upgrade is

complete.

2. From the Main Menu, type

7

, Upgrade Software, and press <Enter>.

3. At the Software Upgrade menu, type

2

, Swap Bank, and press <Enter>.

4. At the Software Upgrade menu, type

1

, Software Reset, and press <Enter>. The modem resets

and starts using the new firmware.