Lightning Protection

The metallic ports of the 2370 are suitable for connection to intra-building or unexposed wiring or
cabling only. The intra-building port(s) of the equipment or subassembly MUST NOT be metallically
connected to interfaces that connect to the OSP or its wiring. These interfaces are designed for use as
intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE) and require
isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient
protection in order to connect these interfaces metallically to OSP wiring.
To protect the port against intra-building lightning surges, the RJ45 type ports of 2370 are suitable for
connection to shielded intra-building cabling grounded at both ends.

ESD

The 2370 has been tested and passes the ESD requirements of Test level 4 for air and contact
discharges. However to protect the exposed components from electrostatic damage when removing or
inserting modules requires the proper use of static mitigation procedures such as properly wearing a
wrist strap.

Operation Temperature

The 2370 is designed and Nationally Recognized Test Laboratory (NRTL) tested and verified to
operate between 0°C to 50°C, and type tested for short-term ambient temperature of minus 5°C to
55°C.